Abstract

The purpose of this study was to evaluate neural tube defect (NTD) detection according to whether serum alpha-fetoprotein (AFP) screening or standard ultrasound are performed. Prenatal and neonatal datasets were reviewed to identify pregnancies with NTDs from 1 institution between January 2000 and December 2003. AFP screening was offered < 21 weeks and considered elevated if > or = 2.50 multiples of the median. Standard ultrasound was performed for specific indications in low-risk pregnancies. There were 66 NTDs, 1 per 950 deliveries. AFP sensitivity was 65%. If the gestational age used for AFP calculation was confirmed with ultrasound, sensitivity improved to 86%. The sensitivity of standard ultrasound was 100%, P < .001 compared with AFP screening. NTDs detected with standard ultrasound were identified later in gestation, as examinations were performed for other indications. Standard ultrasound improved NTD detection over AFP screening alone, by improving AFP test sensitivity and identifying NTDs in low-risk pregnancies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.