Abstract
Context. A crucial aspect in addressing the challenge of measuring the core mass function (CMF), that is pivotal for comprehending the origin of the initial mass function (IMF), lies in constraining the temperatures of the cores. Aims. We aim to measure the luminosity, mass, column density and dust temperature of star-forming regions imaged by the ALMA-IMF large program. These fields were chosen to encompass early evolutionary stages of massive protoclusters. High angular resolution mapping is required to capture the properties of protostellar and pre-stellar cores within these regions, and to effectively separate them from larger features, such as dusty filaments. Methods. We employed the point process mapping (PPMAP) technique, enabling us to perform spectral energy distribution fitting of far-infrared and submillimeter observations across the 15 ALMA-IMF fields, at an unmatched 2.5″ angular resolution. By combining the modified blackbody model with near-infrared data, we derived bolometric luminosity maps. We estimated the errors impacting values of each pixel in the temperature, column density, and luminosity maps. Subsequently, we employed the extraction algorithm getsf on the luminosity maps in order to detect luminosity peaks and measure their associated masses. Results. We obtained high-resolution constraints on the luminosity, dust temperature, and mass of protoclusters, that are in agreement with previously reported measurements made at a coarser angular resolution. We find that the luminosity-to-mass ratio correlates with the evolutionary stage of the studied regions, albeit with intra-region variability. We compiled a PPMAP source catalog of 313 luminosity peaks using getsf on the derived bolometric luminosity maps. The PPMAP source catalog provides constraints on the mass and luminosity of protostars and cores, although one source may encompass several objects. Finally, we compare the estimated luminosity-to-mass ratio of PPMAP sources with evolutionary tracks and discuss the limitations imposed by the 2.5″ beam.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.