Abstract

An all-solid fiber-tip Fabry-Perot interferometer (FPI) coated with a nickel film is proposed and experimentally verified for magnetic field sensing with high sensitivity. It is fabricated by splicing a segment of a thin-wall capillary tube to a standard single-mode fiber (SMF), then inserting a tiny segment of fiber with a smaller diameter into the capillary tube, and creating an ultra-narrow air-gap at the SMF end to form an FPI. When the device is exposed to magnetic field, the capillary tube is strained due to the magnetostrictive effect of the nickel film coated on its outer surface. In addition, owing to the unique breakpoint sensitivity-enhancement structure of the air-gap FPI, the elongation of the capillary tube whose length is over 100 times longer than the air-gap width is entirely transferred to the cavity length change of the FPI, and the sensor is extremely sensitive to the magnetic field as proved by our experiments, achieving a high sensitivity of up to 2.236 nm/mT for a linear magnetic field range from 40 to 60 mT, as well as a low-temperature cross-sensitivity of 56µT/°C. The all-solid stable structure, compact size (total length of ∼3.0 mm), and reflective working mode with high magnetic field sensitivity indicate that this sensor has good application prospects.