Abstract

We describe an anatomic, single-bundle, all-inside anterior cruciate ligament (ACL) graft-link technique using second-generation Flipcutter guide pins (Arthrex, Naples, FL), which become retrograde drills, and second-generation cortical suspensory fixation devices with adjustable graft loop length: femoral TightRope (Arthrex) and tibial ACL TightRope–Reverse Tension (Arthrex). The technique is minimally invasive using only four 4-mm stab incisions. Graft choice is no-incision allograft or gracilis-sparing, posteriorly harvested semitendinosus material. The graft is sutured 4 times through each strand in a loop and linked, like a chain, to femoral and tibial adjustable TightRope graft loops. With this method, graft tension can be increased even after graft fixation. The technique may be modified for double-bundle ACL reconstruction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.