Abstract

We demonstrate an all-solid-state potentiometric sensor constructed from solid-state InN/InGaN sensing- and reference electrodes with the epitaxial InN/InGaN layers directly grown on Si substrates. The sensor, evaluated in KCl aqueous solution, exhibits super-Nernstian sensitivity of −78 mV/decade with good linearity for concentrations of 0.01–1 M, which is the physiologically relevant range. Good stability and re-usability are demonstrated by a long-time drift below 0.2 mV h−1 and standard deviation of 8 mV for repeated measurements over 10 d. These properties fulfil the requirements for compact, robust and highly sensitive all-solid-state sensors and sensor arrays.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.