Abstract

An all-digital interface, application specific integrated circuit (ASIC) has been developed for the control and data sampling of a quartz crystal microbalance (QCM)-based electronic nose. The ASIC is capable of measuring QCM resonant frequency between 0 and 11MHz with a resolution of 1Hz and ±1Hz precision. The ASIC has been used to obtain measurements from polymer coated QCM sensors, in conjunction with polymer/carbon-black coated micro-resistance (μR) sensors, in the detection of primary alcohols. A full system-on-a-chip (SoC) electronic nose, currently under test, which supports arrays of eight QCM and eight μR sensors along with on-chip processing capability, is also described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.