Whether or not concrete prism tests (CPTs) developed for assessment of alkali–silica reactivity of aggregates might be suitable for general ASR performance testing of concrete has been evaluated. This paper presents the background for the choice of test procedures and results on how variations in specimen pre-treatment, ASR exposure conditions and prism size influence concrete porosity, moisture state and transport properties. Results from measurements of alkali leaching and prism expansions during the ASR exposure are presented in a separate paper, together with discussion of consequences for ASR test procedures.For ordinary Portland cements and with water-to-cementitious-materials ratio (w/cm) 0.45 and higher it was found that the internal moisture state is sufficiently high in all the assessed procedures to produce ASR expansion. However, for less permeable concretes lack of internal moisture and lower rate of diffusion can significantly reduce the rate and extent of ASR expansion during laboratory performance testing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.