Abstract

Abstract This paper investigates the applicability of the nondestructive testing and evaluation (NDT&E) method using ultrasonic signals to monitor the curing of alkali-activated fly ash-based concrete (AAFC). The evaluation was carried out on AAFC specimens with two different water/binder (W/B) ratios of 0.3 and 0.5 and after curing at 60 °C for 7, 14, and 28 days, respectively. The signals are recorded and analyzed using linear and non-linear ultrasonic techniques. The results show that the non-linear ultrasonic technique has a clear advantage over the linear ultrasonic technique when monitoring the curing of AAFC specimens with a lower W/B ratio. However, the specimens with the higher W/B ratio do not undergo proper curing and therefore do not show clear distinctions between the curing times measured from the two ultrasonic techniques. The unconfined compressive strength (UCS) of the AAFC specimens at different W/B ratios and curing times is also measured. The UCS results showed a good correlation with the ultrasonic results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.