Abstract

In this paper we report on the alignment locking of an in vacuum 77 m long suspended mirror Fabry-Perot cavity. Lock was achieved by mode-matching a 500 mW Nd:YAG NPRO onto a pre-mode cleaner, the output of which was then mode-matched to the suspended cavity. The longitudinal locking was achieved by feeding back to the laser frequency actuator to follow the cavity resonance. Subsequent implementation of a hybrid auto-alignment system enhanced the stability of the circulating power inside the cavity. Preliminary results are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.