Abstract
In this paper we present the performance of two algorithms currently running in the Tile Calorimeter Read-Out Driver boards for the commissioning of ATLAS. The first algorithm presented is the so called Optimal Filtering. It reconstructs the deposited energy in the Tile Calorimeter and the arrival time of the data. The second algorithm is the MTag which tags low transverse momentum muons that may escape the ATLAS muon spectrometer first level trigger.Comparisons between online (inside the Read-Out Drivers) and offline implementations are done with an agreement around 99% for the reconstruction of the amplitude using the Optimal Filtering algorithm and a coincidende of 93% between the offline and online tagged muons for the MTag algorithm. The processing time is measured for both algorithms running together with a resulting time of 59.2 μs which, although above the 10 μs of the first level trigger, it fulfills the requirements of the commissioning trigger ( ∼ 1 Hz). We expect further optimizations of the algorithms which will reduce their processing time below 10 μs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.