Abstract

For a well-known typical model of a leakage signal in the form of a sequence of pixels, horizontal and vertical blank pulses, the differences in frame scanning frequencies for different sizes of monitor screens on rare-crystalline structures and graphics cards of personal computer monitors are considered. The accuracy with which it is necessary to measure the frame rate of the monitor screen in order to form a high-quality noise interference that can muffle the information components of leakage signals through spurious radiation is substantiated. The real spectra of spurious electromagnetic radiation from the screens of monitors on rare-crystalline structures in the short-wave frequency range and the features of measurements of the frequency characteristics of the spectra by Rohde & Schwarz FPH spectrum analyzers are considered. To achieve the required accuracy of measuring the vertical scan frequency, it is proposed to measure the frequencies of harmonics with maximum amplitudes at different frequency sections, and to process the results. Calculation expressions are found for processing the central frequencies of information leakage measured in the areas in order to much more accurately estimate the frame rate of monitors based on rare crystal structures. The sequence of actions for estimating the frame rate of monitors based on rare crystal structures is substantiated. An algorithm of actions has been obtained, which consists in determining the lower and upper values of the numbers of harmonics that correspond to the estimates of the central frequencies, calculating the estimate of the frame frequency and calculating the accuracy of the estimate. If the calculated accuracy estimate is less than the previously justified one, a conclusion is made about a satisfactory measurement of the frame frequency. If necessary, to obtain more accurate results, increase the number of studied frequency sections. The practical use of the obtained expressions for data processing at thirty-two frequency sections is considered, and conclusions are drawn about satisfactory results in terms of the accuracy of measuring the frame frequency when using the usual spectrum analyzer measurement mode.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.