Abstract
In this paper, we report the construction and characterization of a sensor to detect volatile organic compounds, particularly alcohols. The sensor was fabricated by depositing a polydimethylsiloxane sensing film on the surface of a long-period fiber grating (LPFG). The LPFG spectrum, which was taken as the sensor response, was measured in a Teflon chamber, where different concentrations of methanol, ethanol, propanol, and butanol samples were injected. Spectral shifts to lower wavelength were observed for the last three samples. However, a shift to higher wavelengths for the case of methanol was observed, which was attributed to the fact that its refractive index is smaller than the one for PDMS. Therefore, curves of the sensor response in function of concentration were performed using different analysis techniques: analysis in a fixed wavelength, analysis in a fixed spectrum amplitude and spectral analysis trough principal components analysis (PCA) method. The results showed a regular behavior of the responses according to the molecular weight of the samples. A discussion of the use of each technique was performed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.