Abstract

Intrapulmonary percussive ventilation (IPV) is frequently used for airway clearance, together with delivery of aerosolized medications. Drug delivery via IPV alone increases with decreasing percussion frequency and correlates with tidal volume ([Formula: see text]), whereas drug delivery via IPV during invasive ventilation is not well characterized. We hypothesized that drug delivery via IPV-invasive ventilation would differ from IPV alone due to control of ventilation by invasive ventilation. An adult ventilator circuit was used for IPV-invasive ventilation. A normal or a diseased lung model was configured to airway resistance of 5 cm H2O/L/s and lung compliance of 100 mL/cm H2O or to airway resistance of 20 cm H2O/L/s and lung compliance of 50 mL/cm H2O, respectively. The ventilator settings were the following: pressure control continuous mandatory ventilation mode, 10 breaths/min; PEEP, 5 cm H2O; [Formula: see text], 0.21; inspiratory time, 1 s; no bias flow; and inspiratory pressure, 10 or 15 cm H2O for the normal or the diseased lung model, respectively, to reach [Formula: see text] 500 mL with IPV off. Albuterol nebulized from an IPV device was captured in a filter placed before the lung model and quantitated by spectrophotometry. The maximum efficiency of albuterol delivery via IPV-invasive ventilation was not different from that via IPV alone (mean ± SD of loading dose, 3.7 ± 0.2% vs 4.2 ± 0.3%, respectively; P = .12). The mean ± SD albuterol delivery efficiency with IPV-invasive ventilation was lower for the diseased lung model versus the normal model (1.6 ± 0.3% vs 3.2 ± 0.5%; P < .001), which increased with decreasing percussion frequency. In contrast, the mean ± SD [Formula: see text] was lower for the normal lung model versus the diseased model (401 ± 14 mL vs 470 ± 11 mL; P < .001). Albuterol delivery via IPV-invasive ventilation was modulated by percussion frequency but was not increased with increasing [Formula: see text]. The delivery efficiency was not sufficiently high for clinical use, in part due to nebulizer retention and extrapulmonary deposition.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.