Abstract

The relevant limit states for local compression loading on the webs of a rectangular HSS member are reviewed, and the 2016 AISC Specification Chapter J provisions are adapted from their normal application to the single web of a W-shape or I-section to this case. Two recent laboratory tests on matched-width, rectangular HSS-to-HSS cross-connections are described to illustrate the behavior of such connections under branch axial compression. The data from these tests are supplemented by experimental results from a further 76 cross-connection tests, with the branches being either welded plates or welded HSS. From this 78-test database, the existing provisions for local yielding of the chord sidewalls, local crippling of the chord sidewalls, and buckling of the chord sidewalls, are evaluated. Recommendations are made for handling transverse compression loading on HSS webs in the AISC Specification, and a design example is given to illustrate the approach.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.