Abstract

Airway surface liquid (ASL) is difficult to sample. Lavage with an immiscible perfluorocarbon (PFC) liquid to recover ASL was evaluated in cats. Six wild-type cats underwent bronchoscopic lavage with a PFC (perfluorohexane), with the bronchoscope wedged in the feline equivalent of the right lower lobe. Two cats (control animals) were lavaged with a saline vehicle only. Four procedures were performed on each animal at 2-3-week intervals. Ionic composition of ASL was determined by flame photometry. Cats lavaged with PFC showed significantly more acute respiratory distress than those lavaged with saline (respiratory rate following procedure: PFC, 47 +/- 5 min-1 vs. saline, 27 +/- 2 min-1, P < 0.05; O2 saturation: PFC 80 +/- 1% vs. saline, 91 +/- 1%, P < 0.01). The PFC group also had clinical evidence of chronic respiratory compromise (mean respiratory rate before next anaesthetic; PFC, 37 +/- 2 min-1 vs. saline, 20 +/- 3 min-1, P < 0.01). The PFC-lavaged lungs demonstrated persistent radiographic changes and histological evidence of small airways obstruction with distal alveolar damage. Six PFC lavages yielded ASL samples (> 100 microL) which were sufficient for analysis. Mean (+/- SEM) ionic concentrations in these samples were Na+ 157.4 +/- 14.5 mmol L-1, Cl- 150.5 +/- 16.8 mmol L-1 and K+ 10.1 +/- 1.7 mmol L-1. Perfluorocarbon lavage can be used to collect unmodified ASL from the distal lung. However, repeated lavage with perfluorohexane was associated with significant pathological changes in this study.