Abstract

In this study, we aimed to compare supraglottic airway devices (Supreme and i-gel laryngeal mask) with tracheal tube with respect to airway control and efficiency in ventilation and oxygenation. The study included 325 patients of ASA I-II who underwent laparoscopic cholecystectomy. In group 1, the airway was secured using endotracheal intubation (115 patients). In group 2 (103 patients), LMA Supreme was applied, whereas i-gel mask was used for airway management in group 3 (107 patients). Monitoring parameters were recorded and compared using t-test, analysis of variance (ANOVA), Tukey's test and χ2-test. The following parameters were monitored: insertion time, number of attempts for device placement, oropharyngeal seal pressure, etc. Insertion time was longest in group 1 (14.7±1.65 s) as compared to group 2 (15.5±1.05 s) and group 3 (14.1±1.27 s); ANOVA test yielded a statistically significant difference (p<0.01). Insertion success rate was almost identical in all three groups (p=0.907, χ2-test). Comparison of oropharyngeal seal pressure between group 2 (35.95±2.92 cm H2O) and group 3 (36.47±1.43 cm H2O) yielded no statistical difference (p=0.314, t-test). Endotracheal tube, Supreme and i-gel laryngeal masks were shown to be equally efficient in airway management in laparoscopic cholecystectomy. All three devices enabled efficient ventilation and oxygenation despite certain pathophysiological changes associated with laparoscopy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call