Abstract
We report a 22-year-old, 980-lb (445 kg) man with a body mass index of 163 kg/m 2, who needed intubation for tracheotomy surgery, as he was profoundly hypercarbic and reliant on a tight-fitting continuous positive airway pressure mask. Attempts at oral and nasal fiberoptic intubation during topical anesthesia were unsuccessful because of poor patient cooperation and epistaxis. Thus, after awake placement of a size 5 Laryngeal Mask Airway ProSeal LMA; (LMA North America, San Diego, CA), we induced anesthesia using sevoflurane. Then we placed an Aintree stylet (Cook Critical Care, Bloomington, IN) over a fiberoptic bronchoscope, and both were introduced through the LMA into the trachea. We then removed the fiberoptic bronchoscope followed by the LMA. A Parker size 7.5 endotracheal tube was then “railroaded” over the Aintree catheter into the trachea.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.