Abstract

Airway management techniques are aimed at reducing complications associated with artificial airways and mechanical ventilation, such as retained secretions. The impact of airway management techniques on ventilator-associated events (VAEs) varies considerably by modality. Closed-suction techniques are generally recommended but have limited, if any, impact on VAEs. Normal saline instillation during suctioning is not recommended. Devices designed specifically to remove biofilm from the inside of endotracheal tubes appear to be safe, but their role in VAE prevention is uncertain. Subglottic secretion clearance by artificial cough maneuvers is promising, but more research is needed to assess its clinical feasibility. Continuous cuff-pressure management appears to be effective in reducing microaspiration of subglottic secretions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.