Abstract

There are limited data on rates of failure and airway injury with the use of airway exchange catheters. We performed a single-center retrospective analysis of airway exchange catheters to determine the incidence and associated factors for tube exchange failure and airway injury. Among 1177 cases, failed intubation during attempted tube exchange was noted in 73/527 (13.8%). Airway exchange failure rates were greatest during exchange catheter use for double-lumen tube insertion and when intubation was attempted over the catheter postoperatively. Pneumothorax was noted after 1.5% of attempted tube exchanges. Difficult tube exchange was encountered in 6 of 8 patients with pneumothorax.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.