Abstract
Different scenarios of small break loss of coolant accident for pressurized water reactors (PWRs) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator. A limitation of the condensate backflow toward the RPV by the steam flowing in counter current could affect the core cooling and must be prevented. The simulation of counter-current flow limitation conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach. These numerical methods are not yet mature, so dedicated experimental data are needed for validation purposes. In order to investigate the two-phase flow behavior in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD). This setup is devoted to optical measurement techniques, and therefore, a flat test-section design was chosen with a width of 50 mm. The test section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3 (i.e., 250 mm channel height). The test section is mounted between two separators, one simulating the RPV and the other is connected to the steam generator inlet chamber. The hot leg model is operated under pressure equilibrium in the pressure vessel of the TOPFLOW facility of FZD. The air/water experiments presented in this article focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bar. The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplets and bubbles). The counter-current flow limitation was quantified using the variation in the water levels measured in the separators. A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg. Afterward, bigger waves are generated, which develop to slugs. Furthermore, the flooding points obtained from the experiments were compared with empirical correlations available in literature. A good overall agreement was obtained, while the zero penetration was found at lower values of the gaseous Wallis parameter compared with previous work. This deviation can be attributed to the rectangular cross section of the hot leg model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.