Abstract
A question often asked of industrial hygienists is whether or not asbestos fibres can be propagated by air draughts on altered insulating material. An occupational hygiene survey was conducted during the summer of 1999 throughout the steam tunnels of a university campus to determine airborne concentrations of asbestos fibres in order to answer this question. Results were compared with the so-called clearance test standard (0.01 f/ml used in the Province of Quebec) for work liable to produce asbestos dust emission. Some 3.2% of the results were over the clearance test standard when airborne concentrations of asbestos fibres were determined by phase contrast optical microscopy. However, 41.9% of the results were over the clearance test standard when ambient samples were counted by transmission electron microscopy/energy dispersive spectroscopy (TEM/EDS) for asbestos fibres only and reached 48.4% for all TEM mineral fibres. Of the TEM/EDS results, 3.2% were >0.1 f/ml, the threshold limit value proposed by ACGIH.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.