Abstract

As part of an environmental surveillance program, measurements of 131I in samples of atmospheric aerosols were determined in week-long collection periods at 0.3 km and 1.5 km from a municipal-sewage sludge incinerator located in Albany, New York. During an 11-month period when the sampler was temporarily located near the incinerator, sampling canisters of activated charcoal nearly always contained detectable airborne 131I activity (range of 0.1–6.0 mBq m −3). In contrast, remote concentrations where the sample was normally located were near or below analytical detection limits, both before and after the 11-month relocation. Activities of wet and dry fallout at both locations were below detection limits. The source of 131I in the aerosols associated with the sewage sludge was likely excreta from patients following medical treatments at local hospitals.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.