Abstract

Since 1981, hospitals in Illinois have been prohibited from depositing hazardous infectious waste in landfills without first rendering the waste innocuous. The Illinois Pollution Control Board has adopted regulations indicating that incineration is an acceptable method for disposal of this waste. Emissions from incineration of the plastic-rich hospital waste are not well documented. Stack emissions of particles, hydrochloric acid, carbon monoxide, ethane, ethylene, propane and propylene were measured from a hospital incinerator where all of the hospital's waste (including hazardous infectious waste) was burned. Emission factors developed for each emission component were: particles 1.0–1.6 g/kg waste; hydrochloric acid 3.3–5.3 g/kg; carbon monoxide 1.4–1.8g/kg; ethane <0.002g/kg; ethylene <0.010g/kg; propane <0.012 g/kg; and propylene <0.011 g/kg

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.