Abstract

Air consumption, oxygen uptake (VO 2), carbon dioxide output (VCO 2) and respiratory exchange ratio (RER = VCO 2/VO 2) were measured directly from the self-contained breathing apparatus (SCBA) as 36 professional firefighters (three women) completed scenarios of high-rise stair climbing and fifth floor search and rescue. During stair climbing VO 2 was 75 ± 8% VO 2max (mean ± SD), RER = 1.10 ± 0.10, and heart rate = 91 ± 3% maximum (based on maximum treadmill data). Firefighters stopped climbing on consuming 55% of the air cylinder then descended. In the fifth floor search and rescue VO 2 was slightly lower than stair climbing but RER remained elevated (1.13 ± 0.12) reflecting high anaerobic metabolism. The first low air alarm sounded, indicating 25% of the air remaining in a “30-min cylinder”, during the stair climb at 8 min with 19 of 36 sounding before 12 min. Aggressive air management strategies are required for safety in high-rise firefighting.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.