Abstract

In the report we present the design and test results of the linear transformer driver (LTD) stage that does not need any liquid or compressed gas for insulation inside the cavity and operation of the switches. The only gas, which is used, is air at atmospheric pressure. At peak charge voltage of 85 kV the stage delivers to the matched load of /spl sim/0.15 Ohms the 14 GW power pulse with the rise time of /spl sim/180 ns. The stage is developed to demonstrate the possibility to simplify the LTD technology of the primary energy storages in maintenance and application.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.