Abstract

The electrostatically driven scanning micro mirrors are fabricated for the application to laser scanning display. However, a high voltage is needed for the operation. In order to operate mirror at a low voltage, we investigate the air friction loss of micro mirror with vertically driven comb in vacuum. Due to the operation in vacuum, the rotation angle increases by 52 times larger than that in atmospheric air at the same operation voltage, which corresponds to the decrease of operation voltage by a factor more than 7 at 24.5 kHz resonant frequency. The quality factor depending on air damping is investigated in pressure range from 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sup> Pa to 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> Pa. The theoretical analyses on air friction loss are also presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.