Abstract

A case of fatal air embolism after Küntscher nailing of a fractured femur is described. Necropsy indicated that the only possible means of air entry was through the bone marrow. Subsequent discussion between the surgeon and the pathologist indicated that air must have been forced into the venous circulation through the marrow by repeated removal and reinsertion of nails, which allowed air to fill the punched-out marrow space when the nail was removed, the same air being forced into the marrow sinusoids when the nail was reinserted and hammered into position. This danger may be overcome 1) by allowing the site of operation to flood with blood by placing the patient in a "head up" position; 2) by flooding the operation site with saline; or 3) by assessing the calibre of nail required by radiological means rather than by trial and error.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.