Abstract
With the advancement of technology and the increase in global temperatures, there has been a demand for individual and collective cooling systems in residential and commercial buildings, leaving air conditioning equipment and their respective supports exposed on their facades. The objective of this study is to evaluate the degradation of reinforced concrete supports in a case study. It was found that 49.5% of the buildings have supports for air conditioners in the external area of their facades and of these 69% are reinforced concrete. From the aerial images it was possible to observe cracks in 90% of the supports and 21% presented partial collapse of the structure. It is concluded that the failure in the design of the reinforced concrete support without giving importance to the minimum requirements of coverage and quality control in the manufacture of concrete, are decisive in the increase of porosity and the entry of aggressive agents. The low useful life of these supports is associated with the risk of serious or fatal accidents with the fall of parts of these structures and leads to frequent replacement, demanding more cement consumption and more construction waste.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.