Abstract

This laboratory study evaluated different assistive devices for reducing biomechanical loading during patient turning tasks. Twenty caregivers (18 females and 2 males) performed standardized patient turning tasks with two simulated patients (body mass: 74 kg and 102 kg). The turning tasks were performed in two turning directions (toward vs. away relative to caregivers) using five device conditions: draw sheet, friction-reducing turning sheet, air-assisted transfer device, air-assisted turning device, and no assistive device. Low back and upper extremity muscle activity, trunk and shoulder postures, low back moment, and self-reported usability ratings were evaluated. While all assistive devices reduced trunk flexion, both air-assisted transfer and turning devices reduced the trunk flexion (p's < 0.001) and muscle activity (p's < 0.001) in the erector spinae and triceps compared to no assistive device condition. These results suggest that the air-assisted devices have potential as an effective intervention to considerably reduce physical risk factors associated with caregivers' musculoskeletal disorders in low back and upper extremities.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.