Abstract
Aim:The aim was to evaluate the outcome of Ahmed glaucoma valve (AGV) in post-penetrating-keratoplasty glaucoma (PKPG). Materials and Methods:In this prospective study, 20 eyes of 20 adult patients with post-PKPG with intraocular pressure (IOP) >21 mmHg, on two or more antiglaucoma medications, underwent AG (model FP7) implantation and were followed up for a minimum of 6 months. Absolute success was defined as 5 <IOP <21 mmHg and qualified success as 5 <IOP <21 mmHg with medications or minor procedures.Results:The mean IOP decreased from 42.95 ± 10.24 to 17.69 ± 3.64 mmHg (P <0.001) and the use of medications dropped from 2.92 to 0.39 (P <0.001) after AGV implantation. The absolute success was achieved in 11 eyes and qualified success in 9. There was no significant change in best corrected visual acuity, graft clarity, or graft thickness. Six device-related complications occurred after AGV implantations which were successfully managed with medical or minor surgical therapy.Conclusions:Postkeratoplasty refractory glaucoma managed by AGV implantation revealed a satisfactory outcome up to 6 months of follow-up.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.