Abstract
To assess the agreement between three methods of calculation of mean aortic wall thickness (MAWT) using magnetic resonance imaging (MRI). High-resolution MRI of the infrarenal abdominal aorta was performed on 70 subjects with a history of coronary artery disease who were part of a multi-ethnic population-based sample. MAWT was calculated as the mean distance between the adventitial and luminal aortic boundaries using three different methods: average distance at four standard positions (AWT-4P), average distance at 100 automated positions (AWT-100P), and using a mathematical computation derived from the total vessel and luminal areas (AWT-VA). Bland-Altman plots and Passing-Bablok regression analyses were used to assess agreement between methods. Bland-Altman analyses demonstrated a positive bias of 3.02+/-7.31% between the AWT-VA and the AWT-4P methods, and of 1.76+/-6.82% between the AWT-100P and the AWT-4P methods. Passing-Bablok regression analyses demonstrated constant bias between the AWT-4P method and the other two methods. Proportional bias was, however, not evident among the three methods. MRI methods of measurement of MAWT using a limited number of positions of the aortic wall systematically underestimate the MAWT value compared with the method that calculates MAWT from the vessel areas.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.