Abstract
This study aimed to determine the agreement between fat-free mass (FFM) estimates from bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA) and their use in estimating resting metabolic rate (RMR) in men undergoing resistance training. Thirty healthy resistance-trained men (22.7 ± 4.4 years, 70.0 ± 8.7 kg, 174.6 ± 6.7 cm, and 22.9 ± 2.3 kg/m2) were evaluated. The equation developed by Tinsley et al. (RMR = 25.9 × fat-free mass [FFM] + 284) was adopted to calculate the RMR. DXA was used as the reference method for FFM. Furthermore, FFM was also estimated by BIA using a spectral device. No significant difference (p > 0.05) was observed between DXA (1884.2 ± 145.5 kcal) and BIA (1849.4 ± 167.7 kcal) to estimate RMR. A positive and significant correlation (r = 0.89, p < 0.05) was observed between DXA and BIA estimates of RMR. The mean difference between methods indicated that BIA presented a bias of -34.8 kcal. These findings suggest that using FFM derived from DXA or BIA results in similar RMR estimates in resistance-trained men.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the International Society of Sports Nutrition
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.