Abstract

Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland–Altman analysis and the Lin’s coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, root mean square of successive differences, SD1, SD2, low frequency, high frequency), the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device.

Highlights

  • Clinical evaluation of cardiac function gains more and more importance in the assessment of training status and welfare in equine industry and relies nowadays mainly on portable devices

  • Our study shows that when comparing recordings obtained during exercise in horses using an ECG or a heart rate meter (HRM), agreement is poor between measures of the heart rate variability (HRV) analysis, with the exception of heart rate (HR) and RR-interval

  • This study allowed us to evaluate the agreement on HRV analysis between HRM and ECG during exercise

Read more

Summary

Introduction

Clinical evaluation of cardiac function gains more and more importance in the assessment of training status and welfare in equine industry and relies nowadays mainly on portable devices. This later technique is known as heart rate meter (HRM) Both types of devices allow to evaluate the electric function of the heart at rest and during exercise. The RR intervals can be extracted and a heart rate variability (HRV) analysis can be performed from both devices using suitable functions of the accompanying software. The repeatability was reported good, but the reliability was reported as good to poor; especially a higher day-to-day variability in short-term recording has been reported [31, 32] None of these studies reported agreement for recordings obtained during exercise. The purpose of this study was to assess the agreement of the most commonly used measures of HRV obtained with the two devices

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.