Abstract

To compare agreement level and identify reasons for disagreement between grading of mydriatic digital photographs in a diabetic retinopathy screening service and hospital eye service biomicroscopy grading. Structured examination findings leading to automatically calculated National Screening Committee grades recorded on an electronic medical record system in the hospital eye service at the first clinic visit after diabetic retinopathy screening service referral between April 2006 and November 2007 were retrospectively compared with the grade at the screening visit that prompted referral. In cases of disagreement, screening images were reviewed. Data on 452 eyes (226 patients) were analysed. For retinopathy, hospital eye service slit-lamp biomicroscopy grades were: R0 (no diabetic retinopathy) in 63 eyes; R1 (background retinopathy) in 251 eyes; R2 (pre-proliferative) in 129 eyes and R3 (proliferative) in nine eyes. Diabetic retinopathy screening service grades were in agreement in 350 eyes (77.4%), showed a lower grade in 59 eyes and a higher grade in 43. Agreement was moderate (κ=0.60). The most common reason for disagreement was overgrading of R1 by clinicians. Hospital eye service biomicroscopy maculopathy grades were: M0 (no maculopathy) in 366 eyes and M1 (maculopathy) in 86 eyes. Diabetic retinopathy screening service grades were in agreement in 327 eyes (72.3%), showed a lower grading in five eyes and a higher grade in 120 eyes. Agreement was moderate (κ=0.41). The commonest cause for disagreement was clinicians failing to identify fine macular exudates. This study of routine clinical services demonstrates moderate agreement between non-medical grading of mydriatic digital retinal photography images and hospital slit-lamp biomicroscopy grading of patients referred with diabetic retinopathy. The majority of errors in grading were attributable to errors by hospital doctors, usually in the direction of under-grading which could be a potential source of clinical risk if treatment is delayed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.