Abstract

Silver Nanowire-Polyaniline (AgNWs-PANI) composite modified glassy carbon electrode (GCE) was fabricated for the sensitive electrochemical determination of 4-nitrophenol (4-NP). AgNWs-PANI composite was synthesized in two steps process. The synthesized AgNWs-PANI was characterized by UV–vis, FTIR, SEM and TEM analysis. The electrochemical reduction determination of 4-NP under optimized conditions exhibited a reduction peak at −0.77V with higher current response compared with bare GCE and AgNWs modified glassy carbon electrode (AgNWs/GCE). Effect of pH and scan rate was investigated to examine the proton transfer number, electron transfer number, electron transfer coefficient and standard rate constant of electrode. Under optimized condition, the reduction peak current and the concentration of 4-NP exhibits the linear relation with the concentration range from 0.6–32μM, and the limit of detection was determined to be 52nM (S/N=3). Although, AgNWs-PANI/GCE were applied to detect the determination the 4-NP in real water samples at the recover ranging from 97.0–101.5%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.