Abstract

AbstractAging management of spent fuel storage facility may follow lessons learned from literature for nuclear power plant and a review for spent fuel dry cask storage system by US NRC, DOE, by German BAM, that by Japan NISA, etc. Namely, the essence of systematic approach to aging management includes Understanding aging, Plan (Development and optimisation of activities for aging management), Do (Managing aging mechanisms), Check (Monitoring, inspection and assessment), and Act (Maintenance). The PDCA cycle will optimise the systematic approach to the aging management. An aging management programme (AMP) for the storage system over the period of extended storage will address uncertainties in the safety relevant functions of the system that may otherwise be impaired by aging mechanisms. The AMP identifies system, structure and components (SSCs) that need specific actions to mitigate aging and ensures that no aging effects result in a loss of their intended function of the SSCs, during an intended licensed ...