Abstract

Aging coefficient and creep coefficient are important parameters for creep analysis of any structure. With the aim to obtain those parameters, an experimental investigation is carried out on sealed concrete. Altogether ten specimens were tested, out of which four were for creep, two for shrinkage and remaining four for relaxation test. A year of relaxation test and two years of creep test results were analyzed to compute aging coefficient and creep coefficient. From regression analysis of observed and calculated aging coefficient using formula of Bazant and Kim, modification for aging coefficient is performed and extrapolation equations are generated. Instead of ACI model, B3 model has been used to obtain compliance function as the parameters of B3 model seems more relevant to creep mechanism of concrete compared to that of ACI model.