Abstract

Improving the collection efficiency for particles smaller than 1 μm on every precipitator is important. We sought to improve the collection of these particles on an ESP due to particle agglomeration. Particles are charged by ac corona discharge in a precharger and agglomerated by a dc electric field in an agglomerator downstream of the precharger. Diesel exhaust particles were used as particulate matter for the experiments. The distribution of particle size was measured using a particle counter and a scanning electron microscope. By these methods, particles as small as 0.01 μm could be counted. Results showed the agglomeration between particles at ac corona discharge operating mode. The concentration of particles smaller than approximately 0.35 μm decreases, and that of particles larger than approximately 0.35 μm increases in the agglomerator. The agglomeration rate increases with increasing applied voltage, then saturates. These results may be due to the size distribution and to decrease of concentration by agglomeration. © 1999 Scripta Technica, Electr Eng Jpn, 130(1): 30–37, 2000

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.