Abstract

Hypoxia is a common feature of many diseases such as solid tumors. The measurement and imaging of oxygen (O2) are extremely important for disease diagnosis and therapy evaluation. In this work, the afterglow/fluorescence dual-emissive ratiometric O2 probe based on a photochemical reaction-based afterglow system is reported. The afterglow is highly sensitive to O2 because the O2 content is directly related to the 1O2 yield and eventually affects the afterglow intensity. The O2-insensitive fluorescence of an emitter can serve as an internal reference. As the O2 concentration changes from 0.08 to 18.5 mg L-1, the ratio value shows a remarkable 53-fold increase. Compared with the intensity of a single peak, the ratiometric signal can eliminate the interference of the probe concentration to achieve higher accuracy. This afterglow/fluorescence dual-emissive ratiometric O2 probe is successfully applied to hypoxia imaging in tumor-bearing mice, which may further promote the development of O2 sensing in the biomedical field.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.