Abstract

ObjectivesTo assess the extent of staff exposure to aerosol generation in common pediatric otorhinolaryngological procedures (tonsillotomies, adenoidectomies, and tympanostomies) and determine the surgical phases responsible for most aerosol generation in these procedures. MethodsAerosol generation was measured during 35 pediatric otolaryngological procedures using an Optical Particle Sizer that measures aerosol concentrations for particle sizes between 0.3 and 10.0 μm. The different phases of and instruments used in each procedure were logged. Operating room background aerosol levels and coughing were used as references. ResultsTotal aerosol concentrations were significantly higher during tonsillotomies and adenoidectomies when compared to tympanostomies (p=0.011 and p=0.042) and to empty room background aerosol concentrations (p=0.0057 and p<0.001). Aerosol concentration during tonsillotomies did not differ from coughing, which is considered as standard for high-risk aerosol procedures. During tympanostomies, aerosol concentrations were even lower than during perioperative concentrations. No statistically significant difference in aerosol generation comparing suction, electrocautery, cold instruments, and paracentesis was found. ConclusionAccording to the results of this study, tympanostomies are low-risk aerosol-generating procedures. On the other hand, paediatric tonsillotomies produced aerosols comparable to coughing, pointing to them being significantly aerosol-producing procedures and viral transmission is theoretically possible intraoperatively.