Abstract

The use of threshold Cherenkov detectors for the identification of high momentum particles in high energy physics experiments is connected with the efficiency of detection of light in the aerogel. As one goes lower in the refractive index, less photons are emitted, and more attention should be paid to the improvements of the detection efficiency. The light integration box method relies on photomultipliers of large size and requires even two of them. We have studied the possibility to use a thin focalizing element (Fresnel lens) between the aerogel and the photomultiplier to focalize the light onto a smaller diameter photomultiplier. The results show that for good aerogel and low indices of refraction ( < 1.01 ) the scheme with the aerogel and the Fresnel lens may be superior and less costly than the conventional set-up.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.