Abstract
In order to utilize the shock tube for quantitative investigations of some aerodynamic problems a thin platinum film resistance thermometer was developed for heat transfer rate measurements. The present report describes the construction and calibration of the heat transfer gage. Since the experimental technique presents a major problem this investigation has been carried out in the straight section of the shock tube where the flow conditions are well defined and readily measured. These flow conditions were calculated utilizing the most recent NBS data on air properties at high temperatures. The flow conditions were also measured utilizing the heat transfer gage and several independent experimental techniques, and good agreement was found with the equilibrium flow calculations after an initial period of 30 - 50 μ sec. Measurements of the heat transfer rate at the forward stagnation point and on the circumference of a circular cylinder are reported and compared with the theoretical calculations of L. Lees. A method for deduction of surface pressure distribution from the laminar boundary-layer heat transfer data is also presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.