Abstract

The pressure-flow relationship was examined in excised canine and human larynges with and without a vocal tract. Canine and human larynges were prepared and cut in the midsagittal plane from the top to about 10 mm below the vocal folds. The right half was removed and replaced with an acrylic plate. The vocal tract was simulated initially with a 15-cm plastic tube and later with a vocal tract model with an area function resembling "ah." Simultaneous recordings were made of the glottal pressure, mean subglottal pressure, and average airflow at various levels of adduction. Preliminary data indicated that the pressure-flow relationships were similar to those of a full larynx and were almost linear. The addition of the vocal tract increased the glottal resistance by moving these pressure-flow lines to the lower-flow and higher-pressure region. The human larynx appears to phonate more easily than the canine larynx on the laboratory bench and has lower phonation threshold pressures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.