Abstract

This paper presents a numerical investigation of the smart load control on an Upwind/NREL 5 MW reference wind turbine under the IEC extreme wind shear (EWS) condition utilizing newly developed aero-servo-elastic platform. The control action was implemented through the local perturbation of a deformable trailing edge flap (DTEF) per blade, which was driven by a smart rotor system, based on the FAST/Aerodyn and Matlab/Simulink codes. Results showed that, compared with the original collective pitch control method, the aerodynamic load in terms of blade flapwise root moment and tip deflection were effectively reduced. Furthermore, the smart rotor control also positively affected other components of the drive-chain as well as generator power and pitch system. It was found that the smart control effect altered the nature of the flow-blade interactions and changed the in-phased fluid-structure synchronization into much weaker couplings. As a result, the damping of the fluid-blade system was significantly enhanced, leading to great attenuation in the EWS load on both rotor and other drive-chain components.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.