Abstract

The ability to locate the defects in materials is one of the major attrations of the acoustic emission(AE) technique. The most conventional method for planar AE source localization is to place three or more AE sensors on the plate and to determine the source position by measuring the differences in the arrival times of the AE wave at the sensors, which is called as triangulation method. But this method can not be applied in the material of which elastic wave propagtion velocity is not known. In this paper, we propose two methods, vector method and error minimization method, for AE source location on the material with unknown AE wave velocity. In this method, it is not needed to know the propagation velocity previously, that is, we can apply this method to arbitrary material of which properties are not known exactly. Also, in this paper, the robustness to the error in the measurement of time differences are discussed for both methods. Finally, in order to evaluate the actual performances, experiments using a pencil lead break as the AE source were carried out on the aluminum plate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.