Abstract

BackgroundIt is unclear whether vasopressors can be safely administered through a peripheral intravenous (PIV). Systematic review and meta-analysis methodology was used to examine the incidence of local anatomic adverse events associated with PIV vasopressor administration in patients of any age cared for in any acute care environment.MethodsMEDLINE, EMBASE, CINAHL, the Cochrane Central Register of controlled trials, and the Database of s of Reviews of Effects were searched without restriction from inception to October 2019. References of included studies and related reviews, as well as relevant conference proceedings were also searched. Studies were included if they were: (1) cohort, quasi-experimental, or randomized controlled trial study design; (2) conducted in humans of any age or clinical setting; and (3) reported on local anatomic adverse events associated with PIV vasopressor administration. Risk of bias was assessed using the Revised Cochrane risk-of-bias tool for randomized trials or the Joanna Briggs Institute checklist for prevalence studies where appropriate. Incidence estimates were pooled using random effects meta-analysis. Subgroup analyses were used to explore sources of heterogeneity.ResultsTwenty-three studies were included in the systematic review, of which 16 and 7 described adults and children, respectively. Meta-analysis from 11 adult studies including 16,055 patients demonstrated a pooled incidence proportion of adverse events associated with PIV vasopressor administration as 1.8% (95% CI 0.1–4.8%, I2 = 93.7%). In children, meta-analysis from four studies and 388 patients demonstrated a pooled incidence proportion of adverse events as 3.3% (95% CI 0.0–10.1%, I2 = 82.4%). Subgroup analyses did not detect any statistically significant effects associated with stratification based on differences in clinical location, risk of bias or design between studies, PIV location and size, or vasopressor type or duration. Most studies had high or some concern for risk of bias.ConclusionThe incidence of adverse events associated with PIV vasopressor administration is low. Additional research is required to examine the effects of PIV location and size, vasopressor type and dose, and patient characteristics on the safety of PIV vasopressor administration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.