Abstract

Tidal peritoneal dialysis (TPD) was introduced in 1990 in the hopes of improving dialysis efficiency. Studies comparing low dialysate flow rates show that tidal peritoneal dialysis has no clearance advantage over intermittent peritoneal dialysis (IPD). With high dialysate flow rates, TPD may be superior or similar to IPD in efficacy, but it is expensive because of the high volumes of dialysis solution used. However, it provides better fluid flow mechanics and more comfort to the patient owing to fewer alarms and less pain during inflow and outflow.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.