The research proposes a methodology of high-rate cavitation tests significantly decreasing testing period as well as increasing the accuracy of specifying a cavitation characteristic. To specify it, the tests without holding up consumption are conducted; however, at the pump inlet the rate to minimize pressure is increased. To decrease a test discrepancy, the data logging system is introduced. The research determines the high-rate pressure decreases without holding up consumption; it does not impact the accuracy to specify the cavitation characteristic and minimizes pump operation under the cavitation conditions diminishing erosive action. Automation significantly minimizes labour intensity during tests and improves the accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.