Abstract

Abstract: There is an increasing demand for jumbo shapes in the construction of high-rise buildings. Super jumbos are very heavy rolled wide flange sections with up to 140 mm flange thickness and weigh up to 1377 kg/m. However, there is a lack of knowledge of the behavior of these types of construction, especially under seismic loading. In this paper, a tubular reduced section (RBS) is designed. A tubular reduced beam section (RBS) is made by replacing a part beam with a steel tube at a suitable location of the beam plastic hinge.