Abstract
Abstract: There is an increasing demand for jumbo shapes in the construction of high-rise buildings. Super jumbos are very heavy rolled wide flange sections with up to 140 mm flange thickness and weigh up to 1377 kg/m. However, there is a lack of knowledge of the behavior of these types of construction, especially under seismic loading. In this paper, a tubular reduced section (RBS) is designed. A tubular reduced beam section (RBS) is made by replacing a part beam with a steel tube at a suitable location of the beam plastic hinge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal for Research in Applied Science and Engineering Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.