Abstract

The present paper deals with nanofiltration (NF), ultrafiltration (UF) and ozonization pilot scale tests for revamping and improvement of an industrial plant that treats wastewaters coming from a wide range of hazardous industrial processes. Tests demonstrated that the best treatment is NF whose feed stream comes from sand filters rather than first ozonization stage before final discharge of the effluent. NF rejection coefficients resulted to be 31% for TDS, 94% COD, 9% Cl–, 47% surfactants, 66% phenols and 91% SO42–. UF was tested as NF pre-treatment but results were not so promising in terms of rejection and permeate flux, as well as fouling reduction. Other experimental tests were carried out in order to understand where to recycle the NF retentate: the best treatment in terms of COD reduction and biodegradability was ozonization followed by recycling to the physico-chemical stage. In the same manner, it was found that ozonization of the NF permeate is the best process solution before final treatment and discharge of the effluent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.